Building entries

Single building entry MIS

with membrane injection system

MIS100D 1x58-64 Gas

Single building entry MIS - with membrane injection system
USP
  • Universal building entry with membrane injection system for drill holes in the most common types of wall
  • Controlled ejection of resin through slit membrane hose
Universal house entry with membrane injection system for drill holes in the most common wall types for inserting and sealing the gas section through the cellar wall. In addition, two micropipes 7 mm or 10 mm can be inserted.
Single building entry MIS - with membrane injection system

Facts

Advantages:

  • is pushed directly onto the gas fitting
  • Not necessary to restore basement seal to DIN 18533

Scope of delivery:

  • 1 packing unit: 6 items

Dimensions:

  • For core drills Ø: 99 - 103 mm
  • For wall thicknesses: from 240 to 600 mm

Properties:

  • DVGW-certified

Application range:

  • Water exposure class DIN 18533: W1-E and W2.1-E
  • Waterproof concrete stress class 1 and 2
  • For gas combined building entries manufactured by Schuck and RMA DN25
  • Suitable for 2 speed-pipes 7 mm or 10 mm

Material:

  • Flange component, wall rosette, membrane hose: EPDM
  • Resin filler hose: PE
  • Fast arrangement fixture: glass fibre reinforced polyamide/ABS
  • Sealing tape: butyl

Tightness:

  • gastight and watertight to 1.0 bar

Tests/Standards:

  • DVGW VP 601
Downloads

Installation instructions

Test reports

Schulungsunterlagen

Data sheet & tender specification

For download of data sheet and tender specification please configurate the product in the section below and download via the symbol Download symbol

Tender specifications