Building entries

Membrane injection system

for buildings with a basement

MIS100ND VT63

Membrane injection system - for buildings with a basement
USP
  • No groundwork at the property
  • Universal building entry with membrane injection system for drill holes in the most common types of wall
  • Controlled ejection of resin through slit membrane hose
For the reliable sealing of drinking water, power or telecommunications services. A drilling rocket is used to excavate a continuous empty conduit route from the basement of the building to the edge of the property.
Membrane injection system - for buildings with a basement

Facts

Advantages:

  • Can be fully installed from the inside of building
  • Ideal for applications in which the building connection route has been built over or is difficult to access

Scope of delivery:

  • 1 piece of octagonal inner sealing element
  • 1 piece of MIS 100/VT63 flange unit with sleeve pipe and connection sleeve
  • 2 pieces of self-tapping screws M8x45 and washers for sealing service lines
  • Outer sealing element with injection hose
  • 2 pieces of twist protection flaps

Dimensions:

  • For core drills: ID 99 - 103 mm
  • For wall thicknesses: from 240 to 600 mm

Application range:

  • Water exposure class DIN 18533: W1-E
  • Waterproof concrete stress class 1 and 2

Material:

  • Front plate: glass fibre reinforced polyamide
  • Sealing rubber, flange, seal insert and counter-bearing: EPDM
  • Pipe: PVC-U
  • Screws and washers: stainless steel V2A (AISI 304L)

Tightness:

  • gastight and watertight to 1.0 bar